Prefabricated Data Center

All Products


undefined
+
  • undefined

Prefabricated Data Center

Prefabricated data center through deepening the design, equipment selection and control strategy optimization, as far as possible to improve the efficiency of the system, reduce the overall PUE value of the system. According to different project sites, when the system load rate is 250, the PUE of the data center shall be designed as follows: the annual average PUE ≤ 1.15 and the limit PUE ≤ 1.40 in Class A areas (Huailai, Tianjin, Gui 'an, Beijing and other cities where the average hourly dry bulb temperature is lower than 15 ℃ throughout the year); the annual average PUE≤ 1.20 and the limit PUE≤ 1.40 in Class B areas (Yizheng, Nanjing, Shanghai and other cities where the annual hourly average temperature is higher than 15 ℃ and lower than 20 ℃); The annual average PUE≤ 1.25 and the limit PUE≤ 1.40 in Class C areas (Qingyuan Chongqing, Changzhou Shenzhen and other cities where the annual hourly dry bulb temperature average is higher than 20 ℃).

Prefabricated customized boxes are used, which are divided into low-voltage warehouse, medium-voltage warehouse, machine warehouse and spare parts warehouse according to different functions, including all power distribution units such as medium and low-voltage power distribution cabinets, transformers and various monitoring components in Shengdao. Decoration, equipment installation, wiring, system integration and debugging are completed in the factory. At present, there are mainly two types of container-type square warehouse and skid-type square warehouse.

 

Keywords: power distribution module container

Inquiry now

Product Description

Prefabricated data centers are deeply customized, cluster-deployable, integrated delivery, and ultra-efficient integrated product data centers. The granularity from small to large depends on the square warehouse level (boxboxbox), module level (block), building level (building) and park level (base). Several square warehouses form one, several, several square warehouses form a group of modules, several modules, several modules, several modules combined with buildings to form a hangar, and several buildings to form a park. Prefabricated data center architecture runs through multiple stages of design, procurement, delivery acceptance and operation. Therefore, the amount of construction work on site should be minimized. Maximize more equipment integration work to be completed in the factory warehouse. Only splicing between warehouses and necessary equipment and pipeline connection shall be carried out on the project site. Through product optimization, the working time for on-site assembly, commissioning, power transmission, testing, rectification and acceptance shall be controlled at about 3 months.

Similar Other Products

Leave us a message

Please fill in the correct contact information and we will reply to you as soon as possible. Belt*Number is required.

Submission
%{tishi_zhanwei}%

Search

%{tishi_zhanwei}%