NPX06-Z9 type
Classification:
NPX06-Z9 type
In today's highly developed information society, the role of information network as social infrastructure is increasing day by day. Safe and efficient management of the use of server systems has become the most important issue for enterprises. Longxing has developed an integrated container rack and Internet data center cabinet "NPX06-Z type", which is designed according to YD/T1819 and YD/T2319 standards.
Prefabricated customized boxes are used, which are divided into low-voltage warehouse, medium-voltage warehouse, machine warehouse and spare parts warehouse according to different functions, including all power distribution units such as medium and low-voltage power distribution cabinets, transformers and various monitoring components in Shengdao. Decoration, equipment installation, wiring, system integration and debugging are completed in the factory. At present, there are mainly two types of container-type square warehouse and skid-type square warehouse.
Keywords: power distribution module container
Product Description
Product features:
> The network cabinet (integrated container) for NPX06-Z9 data equipment can provide the mode of front blower cabinet and lower blower cabinet, with air intake hood at the bottom to adjust the air intake.
> Successfully achieved high shock resistance and high functionality, as a pioneer in information and communication cabinets, providing reliable products that are always "safe" and "assured.
> According to user needs, the front door of the cabinet can be equipped with a glass door or a mesh door, so as to realize the lower air supply heat dissipation or the front air supply heat dissipation.
> Front supply air door specifications: front door G, H, rear door G, H
> Lower air supply door specification: front door F or I, rear door G, H
Technical requirements:
> Environmental conditions
Working temperature:-5 ℃- 40 ℃
Relative humidity: ≤ 85%(+30 ℃)
> Introduction of power supply voltage: AC 220V:187-240V
> When the user needs, the data network cabinet can be provided with lower air intake or forward air intake cabinet. The cabinet has air flow organization and cooling effect.
> Provide network interface when user needs
> Insulation resistance: insulation resistance of each live circuit in the cabinet to ground (or cabinet body)> 10MΩ
> insulation strength: each live circuit in the cabinet should be able to withstand 2500V, 50Hz real to the ground (or cabinet body) and between two non-electrically connected live circuits.
Test sine voltage for 1min, no breakdown or arcing, leakage current <10mA
> The plastic material in the cabinet is flame retardant
> Perfect grounding system