NPX06-Z11 type
Classification:
NPX06-Z11 type
In today's highly developed information society, the role of information network as social infrastructure is increasing day by day. Safe and efficient management of the use of server systems has become the most important issue for enterprises. Longxing has developed an integrated container rack and Internet data center cabinet "NPX06-Z type", which is designed according to YD/T1819 and YD/T2319 standards.
Prefabricated customized boxes are used, which are divided into low-voltage warehouse, medium-voltage warehouse, machine warehouse and spare parts warehouse according to different functions, including all power distribution units such as medium and low-voltage power distribution cabinets, transformers and various monitoring components in Shengdao. Decoration, equipment installation, wiring, system integration and debugging are completed in the factory. At present, there are mainly two types of container-type square warehouse and skid-type square warehouse.
Keywords: power distribution module container
Product Description
Features:
> adopt advanced all-welded structure, that is, more than a dozen parts are welded into an integrated overall structure of the cabinet, with beautiful appearance, good integrity, firm structure, strong bearing capacity, static load ≥ 800kg, shelf bearing 200kg without deformation.
> In line with YD5083 standard 8/9 earthquake intensity requirements.
> Front supply air door specification: front door B
The back door B
Technical requirements:
> Environmental conditions
Working temperature:-5 ℃- 40 ℃
Relative humidity: ≤ 85%(+30 ℃)
> Introduction of power supply voltage: AC 220V:187-240V
> When the user needs, the data network cabinet can be provided with lower air intake or forward air intake cabinet. The cabinet has air flow organization and cooling effect.
> Provide network interface when user needs
> Insulation resistance: insulation resistance of each live circuit in the cabinet to ground (or cabinet body)> 10MΩ
> insulation strength: each live circuit in the cabinet should be able to withstand 2500V, 50Hz real to the ground (or cabinet body) and between two non-electrically connected live circuits.
Test sine voltage for 1min, no breakdown or arcing, leakage current <10mA
> The plastic material in the cabinet is flame retardant
> Perfect grounding system